Headlines News :
Welcome To Electrical Laboratory PT.Qualis Indonesia

Conductive Layer Of The Cable Incubator

General Information  
Conductive Layer Of The Cable Incubator to determine the resistance value.  
The device is mainly used to measure resistivity of semi-conducting screen of all levels XLPE cables. It can measure resistance of conductor screen and insulation screen for 35 kV, 110 kV, 220 kV, etc high voltage XLPE cables. Then educe resistivity of semi-conducting screen.   
Kind of test using the equipment:  
- Resistivity of semi-conducting screen test. (IEC 60502-2, SNI IEC 60502-2)  
Measure resistance of conductor screen and insulation screen.  

Features  
- Numbers of the heating box testing once: two samples of resistivity of
  conductor screen and two samples of resistivity of insulation screen.  
- The value displayed: KΩ  

Technical Specifications  
- Overall diameter less than ø55 mm.  
- Effective dimension of heating box: 450 x 450 x 450 mm  
- Temperature of heating box: 0 ~ 120 ℃  
- Temperature deviation of heating box: ±2 ℃.  
- Power measuring device: 100 mw (resistance to ground 1012 Ω)
- Resistance to ground of input terminal of measuring device: 1012 Ω