Ventilator-Aging Test Machine


General Information 
CZ-45 Ventilator-Aging Test Machine used for aging test on insulation and sheathing materials.
Kind of test using the equipment: 
- Aging on insulation & Sheath test. (IEC 6011-1-2, SNI 04-6190.1.2) 
- Aging on complete cable test.(IEC 6011-1-2, SNI 04-6190.1.2) 

Features 
- Available mode,The adjustment buttons attached ventilators, Watt-hour. 
- Within the box SUS # 304 stainless steel, 1.0t fog surface treatment. 
- SECC steel casing used by the paint powder. 

Technical Specifications 
- Temperature range: RT+5℃~200℃ 
- Ventilation amount: 5~150 times/hours. 
- Heating time: RT → 200℃ ≤50 min. 
- Temperature fluctuation: ≤1℃ 
- Temperature deviation: ±1℃ 
- Temperature uniformity: ±2℃ 
- Increase speed test: 5~10 rpm 
- Internal chamber: 450 x 450 x 450 mm (W x H x D) 
- External chamber: 980 x 960 x 660 mm (W x H x D)
- Power supply: AC220V;  50HZ; 4kW; 18A